See what makes Ascend Mechanical the best choice for Stryker OH!
As any homeowner knows, there are a lot of important systems that keep a house running smoothly. Heating and air conditioning and plumbing all need to be in good working order to maintain a comfortable and safe environment. That’s why it’s so important to have a reliable and trustworthy service company that you can call on when you need help. Ascend Mechanical has been providing top-notch service to the people of CITY for over 30 years.
They’re experts in all things HVAC, from repair and maintenance to new installation. They also offer drain cleaning, sewer services, and water heater installation. And their philosophy is simple – they do things the right way, not the easy way. That means they guarantee their work and make sure it’s done right the first time, every time. So if you’re in need of a reliable and competent service company, look no further than Ascend Mechanical. They’re the only call you need to make!
Want to know more about the excellent service we offer? Read below to see what your neighbors in Stryker, OH have to say about our work – then when you need plumbing and HVAC services you can count on, give us a call!
Recent Jobs and Reviews in Stryker, OH
Our Local Reviews by City
- Auburn, IN (3)
- Bryan, OH (145)
- Butler, IN (9)
- Camden, MI (6)
- Defiance, OH (17)
- Edgerton, OH (22)
- Edon, OH (18)
- Fayette, OH (1)
- Hicksville, OH (38)
- Holiday City, OH (1)
- Mark Center, OH (1)
- Montpelier, OH (57)
- Ney, OH (7)
- Paulding, OH (1)
- Pioneer, OH (17)
- Reading, MI (2)
- Sherwood, OH (7)
- Spencerville, IN (1)
- Stryker, OH (8)
- Sylvania, OH (1)
- Wauseon, OH (1)
- West Unity, OH (8)
Job Locations and Reviews
Had a 58 code and that is a wet switch open in Circuit tested and cleaned and checked switch had 1.9 dc volts and also found furnace is leaning the wrong way put shims under coil and clear silicone gap tested and also cleaned drain and trap and tubes and furnace is now level as should be and they do not need to pay for service call per Aaron
Received information from customer in regards to leak from main water supply line leaking in yard. Relayed information to owner and will return as soon as possible to fix issue.
Created job to collect payment for pvc used for TWT.
We recently sold a new 20x25x4 MERV 11 pleated air filter to a customer. This high-efficiency filter is designed to capture dust, pollen, and other airborne particles, significantly improving indoor air quality. The filter’s deep pleats increase surface area, enhancing its lifespan and performance. It fits most standard HVAC systems, ensuring compatibility and ease of installation. Replacing filters regularly is crucial for maintaining optimal system efficiency and ensuring a healthy home environment. Trust our high-quality filters for superior air filtration.
Found system filters were completely clogged. We changed filters and then checked outdoor unit to ensure it was operating properly. System was putting out 53 degree air and was working when we left. Credit card on file was billed for job.
Performed leak search on gas supply to stove and did not locate any leaks. I also did not detect any odor of gas in the home. I throughly checked with bubbles along stove and in basement supply lines.
Drain was plugged between clean out and septic tank. I ran machine through and cleared line. Verified proper operation of all the plumbing
Found bottom of water heater is rusted through and leaking. Heater not repairable. Quoted new 40 gallon NG water heater for mobile home.
Customer called and said AC unit wasn’t working properly, but would like to have maintenance done on it. When we arrive, we found out the condenser was completely clogged and need to be cleaned. We performed a precision tuneup which includes washing the outdoor unit. We also found that blower wheel was dirty and capacitor for indoor motor was weak. Customer wants to hold off on making those repairs. System is now operating properly. Customer would also like a price on adding an extra fan in back bedroom
.
Replaced OEM control board due to there being a burn mark on it. Also I reset a manual reset limit switch. Limit switch was open when we got to the home
For this job, the customer was saying they could smell sewage in the back corner of the house. So I cry underneath the house and found sewage right under where the toilet was and where it was going out side towards the city drain. I found a big crack, just below the toilet and saw signs of leakage around the joints and also saw 2 inch galvanized pipe rusted through. My recommendation is replacing the galvanized pipes from the toilet to the outside drain and replacing all galvanized pipe. As of right now, I was not able to fix the sewage smell.
Return is grossly undersized and has already took out a motor. to insure that this does not happen again and to prevent any damage to the furnace we will be fixing the return. We will be running new properly sized duct work to the three existing returns. We will be setting the existing furnace on a base and installing a 20x25x5 filter rack on the side. We will be installing a new return drop. We will be installing a new return trunk that will a attaching to the three returns. We will be moving the wood burning coil to the supply side on the furnace.(we will supply fittings and the customer will supply the piping)
Found trap was clogged and flame sensor was dirty. Prior to cleaning flame sensor my reading was 1.5 uADC after cleaning flame sensor my reading was 3 uADC. I then removed and cleared debris from trap. After hooking up trap and starting furnace the collector box condensation was able to drain properly and I observed a large amount of condensation going through trap further verifying prior clog. All items are routine maintenance items not covered under warranty. I recommend routine maintenance through Ascend Mechanicals Gold Plan Membership for preventative maintenance.
Customer says there was sewage smell coming from air vent underneath the sink downstairs, the air vent flapper was not working a lot of air to come through. We are changing the auto air vent. We also tested all drains to make sure they were working properly. If we have to come back for problems with smell again we will need to cap where the air vent goes in
Re-venting Furnace out the side wall and externally rising 5 to 6 feet.
For this job, I removed the temporary fan motor and installed the OEM motor. I also install a medium Turbo cap and check the operations of the furnace. The part is under warranty, but the labor was not. I found the furnace is working great. But we do need to follow up with the customer about his ductwork As of right now, the furnace is working in normal operation
changed blower motor. New motor works great
Found blown out register. Need to quote register and isolation valve Install draft fan and rollout switch on boiler.
Got information to quote exhaust run
When I arrived on job site, customer was unsure how long the boiler had been out so after checking the system I found that the damper motor was bad so I bypassed it but it still wouldn’t work so I had to bypass it with wires after doing that, the boiler came on a ran for a few minutes, then shut back off. I’ve then found that the high limit switch terminals were corroded and not allowing voltage to pass off Through them, I made the best connections possible with the condition of the switch and then boiler fired off. Boiler was running when I left, we will need to follow up with a price on a new draft motor and rollout switch. Please mail the invoice.
For this job, the customer was having problems geothermal not heating. So I proceeded to check the unit and found a five amp fuse was tripped. While I was checking the geothermal, I had the system on emergency heat had a temp split of 61° and 118°. After I reset the five amp fuse, I turned the system back on the heat pump and was able to get proper readings. I had a temp split of 61° and 92°. I also checked the water split and the temperature of the water as well The customer said they did not have this unit service for a while, so I recommended the customer having a tuneup done to this geothermal. The customer wants us to come back and do a tuneup. I did not find any other issues with this system
For this job, the customers furnace kept running, even though the thermostat was satisfied. Then sometimes it will come on, then shut off a couple times. Even though the stat was satisfied. I found that the thermostat wire was hooked up to the universal thermostat Smart wire module, and when I unhooked it and just connect R and W the furnace seems to be working great. My recommendation to the customer was replacing the two wire that they got and add 18/6 wire. The customer gave me the OK to have that wire replaced. Both labor and part is under warranty and we would need to reschedule to come back. As of right now, the furnace is working.
Found glass fuse to be blown. Replaced fuse and verified proper operation.
Replaced pressure tank and verified everything was working properly.